Brief introduction of IP67 Test method for Protection Class

Publish Time: 2019-01-22     Origin: BSUMWELL


Standard Test method for Protection Class according to EN60529:2000

Experimental conditions for the first eigenvalue 6

Vacuum test of IP6X dust and air mixture against invasion of foreign solid matter.

Vacuum: < 2kpa (20mbar)

Experimental time: 8 hours

Experimental dust: talc powder

Particle diameter distribution < 50um > 75um


Experimental conditions for the first eigenvalue 5

Vacuum test of IP5X dust and air mixture against invasion of foreign solid matter.

Vacuum: < 2kpa (20mbar)

Experimental time: 8 hours

Experimental :dust

Particle diameter distribution: < 1mm > 50um


Second eigenvalue

Protective experiment system of IPx6 for preventing Water intrusion

Experimental device: high pressure water

Experimental time: 1 hour

Experimental conditions for the second eigenvalue 7

Protective experiment system of IPx7 for preventing Water intrusion

Experimental device: intrusive pool

Distance: 1 m from top surface of chassis

Experimental time: 30 minutes


Definition of the first eigenvalue 6: no dust intrusion

Definition of the second eigenvalue 7: the amount of water that does not seep into the chassis for a specified period of time when the case is submerged in water at standard pressure


What is the difference between a waterproof junction box and an electrical sealed box?

Brief introduction of IP67 Test method for Protection Class

Waterproof junction box should be considered in the selection and design of materials

Classification of cable connector products

Cable glands